관심표준 등록 : 표준업데이트 시 알림을 받을 수 있습니다.
PDF : 직접 파일 다운로드 및 인쇄 (마이페이지 확인)
PRINT : 인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current more than 16 A per phase (Adopted CEI/IEC 61000-4-34:2005, first
분야 | 11 : LG Electronics |
---|---|
적용범위 | Preface This is the first edition of CAN/CSA-CEI/IEC 61000-4-34, Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current more than 16 A per phase, which is an adoption without modification of the identically titled CEI/IEC (Commission ?lectrotechnique Internationale/International Electrotechnical Commission) Standard 61000-4-34 (first edition, 2005-10). Scope This part of IEC 61000 defines the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low-voltage power supply networks for voltage dips, short interruptions, and voltage variations. This Standard applies to electrical and electronic equipment having a rated input current exceeding 16 A per phase. It covers equipment installed in residential areas as well as industrial machinery, specifically voltage dips and short interruptions for equipment connected to either 50 Hz or 60 Hz a.c. networks, including 1-phase and 3-phase mains. NOTE 1 Equipment with a rated input current of 16 A or less per phase is covered by publication IEC 61000-4-11. NOTE 2 There is no upper limit on rated input current in this publication. However, in some countries, the rated input current may be limited to some upper value, for example 75 A or 250 A, because of mandatory safety standards. It does not apply to electrical and electronic equipment for connection to 400 Hz a.c. networks. Tests for equipment connected to these networks will be covered by future IEC standards. ------------------------------------------------------------------------------------ Pr?face? Ce document constitue la premi?re ?dition de la CAN/CSA-CEI/IEC 61000-4-34, Compatibilit? ?lectromagn?tique (CEM) - Partie 4-34: Techniques d'essai et de mesure - Essais d'immunit? aux creux de tension, coupures br?ves et variations de tension pour mat?riel ayant un courant appel? de plus de 16 A par phase. II s'agit de l'adoption, sans modifications, de la norme CEI/IEC (Commission ?lectrotechnique Internationale/International Electrotechnical Commission) 61000-4-34 (premi?re ?dition, 2005-10), qui porte le m?me titre. Domaine d’application La pr?sente partie de la CEI 61000 d?finit les m?thodes d'essai d'immunit? ainsi que la gamme des niveaux d'essais pr?f?r?s pour les mat?riels ?lectriques et ?lectroniques connect?s ? des r?seaux d'alimentation basse tension pour les creux de tension, les coupures br?ves et les variations de tension. La pr?sente norme s'applique aux mat?riels ?lectriques et ?lectroniques dont le courant nominal d'entr?e d?passe 16 A par phase. Elle s'applique aux mat?riels install?s dans des environnements r?sidentiels de m?me qu'aux mat?riels industriels, pour l'aspect creux de tension et coupures br?ves des ?quipements, monophas?s et triphas?s, reli?s ? des r?seaux ?lectriques alternatif de 50 Hz ou 60 Hz. NOTE 1 Les mat?riels dont le courant appel? est de 16 A ou moins sont trait?s dans la CEI 61000-4-11. NOTE 2 Il n'y a pas de limite maximale du courant appel? dans la pr?sente norme. N?anmoins, dans certains pays, le courant appel? peut ?tre limit? ? une valeur maximale, par exemple 75 A ou 250 A, ? cause de normes de s?curit? obligatoires. Elle ne s'applique pas aux mat?riels ?lectriques et ?lectroniques destin?s ? ?tre reli?s ? des r?seaux ?lectriques ? courant alternatif de 400 Hz. Les essais pour les mat?riels reli?s ? ces r?seaux seront trait?s dans des normes CEI ? venir. |
국제분류(ICS)코드 | |
페이지수 | 85 |
Edition |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 61000-4-34:2005+AMD1:2009 CSV | Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16 A per phase | 2009-11-26 | 표준 |
2 | IEC 61000-4-34:2005/AMD1:2009/COR1:2009 | Corrigendum 1 - Amendment 1 - Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16 A per phase | 2009-10-30 | 표준 |
3 | IEC 61000-4-34:2005/AMD1:2009 | Amendment 1 - Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipmentwith mains current more than 16 A per phase | 2009-05-13 | 표준 |
4 | CSA IEC 61000-4-34:06 (R2024) | Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current more than 16 A per phase (Adopted CEI/IEC 61000-4-34:2005, first | 2006-01-01 | 표준 |
5 | IEC 61000-4-34:2005 | Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current more than 16 A per phase | 2005-10-17 | 표준 |
IEC TR 61000-2-1:1990 - Electromagnetic compatibility (EMC) - Part 2: Environment - Section 1: Description of the environment - Electromagnetic environment for low-frequency conducted disturbances and signalling in public power supply systems 상세보기
IEC TR 61000-2-3:1992 - Electromagnetic compatibility (EMC) - Part 2: Environment - Section 3: Description of the environment - Radiated and non-network-frequency-related conducted phenomena 상세보기
IEC 61000-4-12:1995 - Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 12: Oscillatory waves immunity test. Basic EMC Publication 상세보기
IEC TR 61000-2-6:1995 - Electromagnetic compatibility (EMC) - Part 2: Environment - Section 6: Assessment of the emission levels in the power supply of industrial plants as regards low-frequency conducted disturbances 상세보기
IEC 61000-5-5:1996 - Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 5: Specification of protective devices for HEMP conducted disturbance. Basic EMC Publication 상세보기
함께 구입한 상품이 존재하지 않습니다.
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기