    IEC 60076-3:2013

    Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
    • 발행일 : 2013-07-31
    • 발행기관 : IEC
    즐겨찾기 장바구니 담기
    닫기

    상품이 장바구니에 담겼습니다.

    장바구니로 이동
    • [영어/불어]PDF 515,500원

    • [영어/불어]PRINT 515,500원

상세정보

분야 TC 14 : Power transformers
적용범위 IEC 60076-3:2013 specifies the insulation requirements and the corresponding insulation tests with reference to specific windings and their terminals. This International Standard applies to power transformers as defined by IEC 60076-1. It also recommends external clearances in air. It gives details of the applicable dielectric tests and minimum dielectric test levels. Recommended minimum external clearances in air between live parts and between live parts and earth are given for use when these clearances are not specified by the purchaser. For categories of power transformers and reactors which have their own IEC standards, this standard is applicable only to the extent in which it is specifically called up by cross reference in the other standards. This third edition of IEC 60076-3 cancels and replaces the second edition published in 2000, and constitutes a technical revision. The main changes from the previous edition are as follows:
- Three categories of transformer are clearly identified together with the relevant test requirements, these are summarised in Table 1.
- Switching impulse levels are defined for values of Um > 72,5 kV.
- The procedure for Induced voltage tests with PD has been revised to ensure adequate phase to phase test voltages.
- The AC withstand test has been redefined (LTAC instead of ACSD).
- Induced voltage tests are now based on Ur rather than Um. - New requirements for impulse waveshape (k factor) have been introduced.
- Tables of test levels have been merged and aligned with IEC 60071-1:2010.
- Additional test levels have been introduced for Um > 800 kV.
- A new Annex E has been introduced, which sets out the principles used in assigning the tests, test levels and clearances in air.
국제분류(ICS)코드 29.180 : 변압기. 반응기
페이지수 118
Edition 3.0

이력정보

No. 표준번호 표준명 발행일 상태
1 IEC 60076-3:2013/AMD1:2018상세보기 Amendment 1 - Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air 2018-03-22 표준
2 IEC 60076-3:2013+AMD1:2018 CSV상세보기 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air 2018-03-22 표준
3 IEC 60076-3:2013상세보기 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air 2013-07-31 표준
4 IEC 60076-3:2000/COR1:2000상세보기 Corrigendum 1 - Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air 2000-12-08 구판
5 IEC 60076-3:2000상세보기 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air 2000-03-21 구판
6 IEC 60076-3:1980/AMD1:1981상세보기 Amendment 1 - Power transformers - Part 3: Insulation levels and dielectric tests 1981-01-01 구판
7 IEC 60076-3:1980상세보기 Power transformers - Part 3: Insulation levels and dielectric tests 1980-01-01 구판

제공형태 닫기

  • PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • 보안PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능
  • PRINT :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • BOOK :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • ZIP :

    압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)
  • CD/DVD :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • DB :

    별도 정보 제공
  • HARDCOPY :

    해외 배송 상품, 최대 3주 소요
  • 바인더 :

    바인더 우편발송, 2~3일 소요
  • 온라인구독 :

    WEB 접속 후 실시간 열람, 출력(1년간)