관심표준 등록 : 표준업데이트 시 알림을 받을 수 있습니다.
PDF : 직접 파일 다운로드 및 인쇄 (마이페이지 확인)
PRINT : 인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
분야 | TC 66 : Safety of measuring, control and laboratory equipment |
---|---|
적용범위 | IEC 61010-031:2015 specifies safety requirements for hand-held and hand-manipulated probe assemblies of the types described below, and their related accessories. These probe assemblies are for direct electrical connection between a part and electrical test and measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment. It has the status of a group safety publication in accordance with IEC GUIDE 104. IEC 61010-031 is a stand-alone standard. This second edition cancels and replaces the first edition published in 2002 and Amendment 1:2008. This edition constitutes a technical revision. This edition includes the following significant changes from the first edition, as well as numerous other changes: a) Voltages above the levels of 30 V r.m.s., 42,4 V peak, or 60 V d.c. are deemed to be HAZARDOUS LIVE instead of 33 V r.m.s., 46,7 V peak, or 70 V d.c. b) Servicing is now included within the scope. c) Extended environmental conditions are included within the scope. d) New terms have been defined. e) Tests for REASONABLY FORESEEABLE MISUSE have been added, in particular for fuses. f) Additional instruction requirements for probe assembly operation have been specified. g) Limit values for ACCESSIBLE parts and for measurement of voltage and touch current have been modified. h) SPACINGS requirements for mating of CONNECTORS have been modified. i) PROBE TIPS and SPRING-LOADED CLIPS requirements have been modified. The PROTECTIVE FINGERGUARD replace the BARRIER with new requirements. j) Insulation requirements (6.5) and test procedures (6.6.5) have been rewritten and aligned when relevant with Part 1. Specific requirements have been added for solid insulation and thin-film insulation. k) The terminology for MEASUREMENT CATEGORY I has been replaced with the designation "not RATED for measurements within MEASUREMENT CATEGORIES II, III, or IV". l) The flexing/pull test (6.7.4.3) has been partially rewritten. m) Surface temperature limits (Clause 10) have been modified to conform to the limits of IEC Guide 117. n) Requirements for resistance of PROBE WIRES to mechanical stresses have been added in Clause 12 and a new Annex D. o) Requirements have been added regarding the prevention of HAZARD from arc flash and short-circuits for SPRING-LOADED CLIPS. p) A new informative Annex E defines the dimension of the 4 mm banana CONNECTORS. |
국제분류(ICS)코드 | 19.080 : 전기 및 전자 시험 및 측정기구 |
페이지수 | 177 |
Edition | 2.0 |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 61010-031:2022 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement | 2022-12-22 | 표준 |
2 | IEC 61010-031:2022 CMV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement | 2022-12-22 | 표준 |
3 | IEC 61010-031:2015+AMD1:2018 CSV/COR1:2018 | Corrigendum 1 - Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement | 2018-08-06 | 구판 |
4 | IEC 61010-031:2015/AMD1:2018 | Amendment 1 - Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement. | 2018-05-29 | 구판 |
5 | IEC 61010-031:2015+AMD1:2018 CSV | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held and hand-manipulated probe assemblies for electrical test and measurement | 2018-05-29 | 구판 |
6 | IEC 61010-031:2015 RLV | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test | 2015-05-29 | 구판 |
7 | IEC 61010-031:2015 | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test | 2015-05-29 | 구판 |
8 | IEC 61010-031:2002+AMD1:2008 CSV | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test | 2008-06-24 | 구판 |
9 | IEC 61010-031:2002/AMD1:2008 | Amendment 1 - Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test | 2008-02-12 | 구판 |
10 | IEC 61010-031:2002 | Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test | 2002-01-10 | 구판 |
IEC 61010-2-031:1993 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-031: Particular requirements for hand-held probe assemblies for electrical measurement and test 상세보기
IEC 61010-2-041:1995 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-041: Particular requirements for autoclaves using steam for the treatment of medical materials, and for laboratory processes 상세보기
IEC 61010-2-043:1997 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-043: Particular requirements for dry heat sterilizers using either hot air or hot inert gas for the treatment of medical materials, and for laboratory processes 상세보기
IEC 61010-2-042:1997 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-042: Particular requirements for autoclaves and sterilizers using toxic gas for the treatment of medical materials, and for laboratory processes 상세보기
IEC TR 61010-3-010:1999 - Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 3-010: Conformity verification report for IEC 61010-2-010, Particular requirements for laboratory equipment for the heating of materials 상세보기
함께 구입한 상품이 존재하지 않습니다.
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기