QUICK

TOP

해외표준 상세정보

관심표준 등록 : 표준업데이트 시 알림서비스

제공형태 더보기

상세정보

분야 ISO/TC 113/SC 2 : Flow measurement structures
적용범위

This document specifies methods for the measurement of flow in rivers and artificial channels under steady or slowly varying flow conditions, using certain types of critical-depth flumes (also known as “standing-wave flumes”). A wide variety of flumes has been developed, but only those critical-depth flumes which have received general acceptance after adequate research and field testing, and which therefore do not require in situ calibration, are considered herein.

The flow conditions considered are uniquely dependent on the upstream head, i.e. subcritical flow must exist upstream of the flume, after which the flow accelerates through the contraction and passes through its critical depth (see Figure 1). The water level downstream of the structure is low enough to have no influence upon its performance.

This document is applicable to three commonly used types of flumes, covering a wide range of applications, namely rectangular-throated, trapezoidal-throated and U-throated. The hydraulic theory behind this document was presented in Reference [7].

This document is not applicable to a form of flume referred to in the literature (sometimes called a “Venturi” flume) in which the flow remains subcritical throughout.

NOTE      The Venturi form of flume is based on the same principle as a Venturi meter used within a closed conduit system and relies upon gauging the head at two locations and the application of Bernoulli’s energy formula.

국제분류(ICS)코드 17.120.20 : 개방관내 유동
페이지수 79
Edition 3

이력정보

No. 표준번호 표준명 발행일 상태
1 ISO 4359:2022상세보기 Flow measurement structures — Rectangular, trapezoidal and U-shaped flumes 2022-12-19 표준
2 ISO 4359:2013/Amd 1:2017상세보기 Flow measurement structures — Rectangular, trapezoidal and U-shaped flumes — Amendment 1 2017-06-16 구판
3 ISO 4359:2013상세보기 Flow measurement structures — Rectangular, trapezoidal and U-shaped flumes 2013-02-08 구판
4 ISO 4359:1983/Cor 1:1999상세보기 1999-10-21 구판
5 ISO 4359:1983상세보기 Liquid flow measurement in open channels — Rectangular, trapezoidal and U-shaped flumes 1983-07-01 구판

제공형태 닫기

  • PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • 보안PDF :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)* 단, 파일이동 및 복사 불가, 1회 다운로드 및 인쇄가능
  • PRINT :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • BOOK :

    인쇄본 우편발송, 2~3일 소요(PDF파일 미제공)
  • ZIP :

    압축파일형태로 제공 (PDF, HTML, TXT, XLS 등으로 구성), 직접 파일 다운로드(마이페이지 확인)
  • CD/DVD :

    직접 파일 다운로드 및 인쇄(마이페이지 확인)
  • DB :

    별도 정보 제공
  • HARDCOPY :

    해외 배송 상품, 최대 3주 소요
  • 바인더 :

    바인더 우편발송, 2~3일 소요
  • 온라인구독 :

    WEB 접속 후 실시간 열람, 출력(1년간)