분야 | TC 99 : Insulation co-ordination and system engineering of high voltage electrical power installations above 1,0 kV AC and 1,5 kV DC |
---|---|
적용범위 | IEC 61936-1:2010+A1:2014 provides common rules for the design and the erection of electrical power installations in systems with nominal voltages above 1 kV a.c. and nominal frequency up to and including 60 Hz, so as to provide safety and proper functioning for the use intended. For the purpose of interpreting this standard, an electrical power installation is considered to be one of the following: a) Substation, including substation for railway power supply; b) Electrical installations on mast, pole and tower; Switchgear and/or transformers located outside a closed electrical operating area; c) One (or more) power station(s) located on a single site. The installation includes generators and transformers with all associated switchgear and all electrical auxiliary systems. Connections between generating stations located on different sites are excluded; d) The electrical system of a factory, industrial plant or other industrial, agricultural, commercial or public premises. The electrical power installation includes, among others, the following equipment: rotating electrical machines; switchgear; transformers and reactors; converters; cables; wiring systems; batteries; capacitors; earthing systems; buildings and fences which are part of a closed electrical operating area; associated protection, control and auxiliary systems; large air core reactor. NOTE: In general, a standard for an item of equipment takes precedence over this standard. This standard does not apply to the design and erection of any of the following: - overhead and underground lines between separate installations; - electric railways; - mining equipment and installations; - fluorescent lamp installations; - installations on ships and off-shore installations; - electrostatic equipment (e.g. electrostatic precipitators, spray-painting units); - test sites; - medical equipment, e.g. medical X-ray equipment. This standard does not apply to the design of factory-built, type-tested switchgear for which separate IEC standards exist. This standard does not apply to the requirements for carrying out live working on electrical installations. This second edition cancels and replaces the first edition, published in 2002. It constitutes a technical revision. The main changes with respect to the previous edition are listed below: - new table of references for additional agreements between manufacturer/contractor/planer and user/orderer/owner (4.1.2); - addition of minimum clearances in air not standardized by IEC but based on current practice in some countries (Annex A); - deletion of nominal voltages (Table 1, Table 2, Clause 5); - addition of regulations for fuses (6.2.15); - simplification of regulations for escape routes (7.5.4); - deletion of special regulations for operating aisles (7.5.4); - modification of clearances for fire protection (Table 3); - modification of safety criteria for earthing systems (10.2.1); - modified curves of permissibly touch voltages (Figure 12, Annex B); - deletion of numbering of subclauses without headlines; - change of "should" to "shall" in many cases or change of subclauses with "should" to a note. This consolidated version consists of the second edition (2010) and its amendment 1 (2014). Therefore, no need to order amendment in addition to this publication. |
국제분류(ICS)코드 |
29.020 : 전기 공학 일반
29.080.01 : 전기 절연 일반 |
페이지수 | 438 |
Edition | 2.1 |
No. | 표준번호 | 표준명 | 발행일 | 상태 |
---|---|---|---|---|
1 | IEC 61936-1:2021 | Power installations exceeding 1 kV AC and 1,5 kV DC - Part 1: AC | 2021-07-07 | 표준 |
2 | IEC 61936-1:2021 CMV | Power installations exceeding 1 kV AC and 1,5 kV DC - Part 1: AC | 2021-07-07 | 표준 |
3 | IEC 61936-1:2010/AMD1:2014 | Amendment 1 - Power installations exceeding 1 kV a.c. - Part 1: Common rules | 2014-02-26 | 구판 |
4 | IEC 61936-1:2010+AMD1:2014 CSV | Power installations exceeding 1 kV a.c. - Part 1: Common rules | 2014-02-26 | 구판 |
5 | IEC 61936-1:2010/COR1:2011 | Corrigendum 1 - Power installations exceeding 1 kV a.c. - Part 1: Common rules | 2011-03-09 | 구판 |
6 | IEC 61936-1:2010 | Power installations exceeding 1 kV a.c. - Part 1: Common rules | 2010-08-31 | 구판 |
7 | IEC 61936-1:2002 | Power installations exceeding 1 kV a.c. - Part 1: Common rules | 2002-10-17 | 구판 |
IEC TS 61936-2:2015 - Power installations exceeding 1 kV a.c. and 1,5 kV d.c. - Part 2: d.c. 상세보기
IEC 61936-1:2021 - Power installations exceeding 1 kV AC and 1,5 kV DC - Part 1: AC 상세보기
IEC 61936-1:2021 CMV - Power installations exceeding 1 kV AC and 1,5 kV DC - Part 1: AC 상세보기
IEC TS 61936-0:2023 - Power installations exceeding 1 kV AC and 1,5 kV DC - Part 0: Principles to be observed in the design and erection of high voltage installations - Safety of high voltage installations 상세보기
IEC 61936-2:2023 - Power installations exceeding 1 kV AC and 1,5 kV DC - Part 2: DC 상세보기
함께 구입한 상품이 존재하지 않습니다.
IEC TS 63134:2020 - Active assisted living (AAL) use cases 상세보기
IEC 60034-5:2020 RLV - Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electrical machines (IP code) - Classification 상세보기
KS B ISO TS 25740-1 - 에스컬레이터 및 무빙워크에 대한 안전요건 — 제1부: 세계공통 필수 안전요건(GESRs) 상세보기
KS B ISO TS 8100-21 - 승객 및 화물 운송용 엘리베이터 —제21부: 세계공통 필수안전요건(GESRs)을 충족하는 세계공통 안전 파라미터(GSPs) 상세보기
KS C IEC TS 62872 - 산업 시설과 스마트 그리드 사이의 산업 공정 측정, 제어 및 자동화 시스템 인터페이스 상세보기